Schneider Electric EGB24090 Miniature Circuit Breaker 480Y/277V 90A

(No reviews yet) Write a Review
SKU:
EGB24090
UPC:
7.85901E+11
Condition:
New
Mounting Mode:
bolt-on
Product Destination:
NF panelboard
Holding Current:
1000 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Circuit Breaker Application:
HACR rated
Net Weight:
3 lb(US)
Electrical Connection:
lugs aluminium
Line Rated Current:
90 A
Warranty:
18 months
Depth:
4.05 in
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Product Or Component Type:
miniature circuit-breaker
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Spaces Required:
2
Width:
1.96 in
Mercury Free:
Yes
Local Signalling:
trip indicator
Product Certifications:
cULus
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Ambient Air Temperature For Operation:
40 °C
[Ue] Rated Operational Voltage:
480Y/277 V AC
Breaking Capacity:
35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
Number Of Spaces:
2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Trip Unit Technology:
thermal-magnetic
Range Of Product:
125 A Frame EDB-EGB-EJB
Number Of Poles:
2
Device Short Name:
EGB
Height:
5.66 in
Module Type:
E-Frame
Protection Type:
short-circuit || overload
Breaking Capacity Code:
G
Trip Unit Rating:
2300-2300 A
  • Schneider Electric EGB24090 Miniature Circuit Breaker 480Y/277V 90A
  • Schneider Electric EGB24090 Miniature Circuit Breaker 480Y/277V 90A
$1,920.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 90A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. HACR rated.