Holding Current:
1000 A
Ambient Air Temperature For Operation:
40 °C
Warranty:
18 months
Number Of Poles:
2
Trip Unit Rating:
2300-2300 A
Product Certifications:
cULus
Depth:
4.05 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
5.66 in
Product Destination:
NF panelboard
Breaking Capacity Code:
G
Protection Type:
overload || short-circuit
Mounting Mode:
bolt-on
Module Type:
E-Frame
Electrical Connection:
lugs aluminium
Circuit Breaker Application:
HACR rated
Width:
1.96 in
Number Of Spaces Required:
2
Mercury Free:
Yes
Trip Unit Technology:
thermal-magnetic
Number Of Spaces:
2
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Range Of Product:
125 A Frame EDB-EGB-EJB
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Line Rated Current:
110 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Net Weight:
3 lb(US)
Product Or Component Type:
miniature circuit-breaker
Device Short Name:
EGB
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Breaking Capacity:
35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
[Ue] Rated Operational Voltage:
480Y/277 V AC
Rohs Exemption Information:
Yes
Local Signalling:
trip indicator
Brochure:
View
Datasheet:
View
  • Schneider Electric EGB24110 Miniature Circuit Breaker 480Y/277V 110A
  • Schneider Electric EGB24110 Miniature Circuit Breaker 480Y/277V 110A
$2,586.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 110A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. HACR rated.