Schneider Electric EGB24125 Miniature Circuit Breaker 480Y/277V 125A

(No reviews yet) Write a Review
SKU:
EGB24125
UPC:
785901128618
Condition:
New
Range Of Product:
125 A Frame EDB-EGB-EJB
Holding Current:
1000 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
miniature circuit-breaker
Depth:
4.05 in
Ambient Air Temperature For Operation:
40 °C
Height:
5.66 in
Number Of Spaces Required:
2
Breaking Capacity Code:
G
[Ue] Rated Operational Voltage:
480Y/277 V AC
Local Signalling:
trip indicator
Protection Type:
overload || short-circuit
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Rating:
2300-2300 A
Electrical Connection:
lugs aluminium
Warranty:
18 months
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Device Short Name:
EGB
Net Weight:
3 lb(US)
Product Destination:
NF panelboard
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Circuit Breaker Application:
HACR rated
Number Of Spaces:
2
Mercury Free:
Yes
Module Type:
E-Frame
Product Certifications:
cULus
Mounting Mode:
bolt-on
Eu Rohs Directive:
Compliant with Exemptions
Breaking Capacity:
35 kA 277 V AC || 65 kA 240 V AC || 35 kA 480Y/277 V AC || 65 kA 120 V AC || 65 kA 120/240 V AC
Line Rated Current:
125 A
Number Of Poles:
2
Trip Unit Technology:
thermal-magnetic
Width:
1.96 in
Brochure:
View
Catalog:
View
Datasheet:
View
$2,586.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 125A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 65 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. HACR rated.