Schneider Electric EJB14025 Miniature Circuit Breaker 277V 25A

(No reviews yet) Write a Review
SKU:
EJB14025
UPC:
785901130512
Condition:
New
Product Certifications:
cULus
Protection Type:
overload || short-circuit
Breaking Capacity Code:
J
Product Destination:
NF panelboard
Mounting Mode:
bolt-on
Circuit Breaker Application:
HACR rated || HID rated
[Ue] Rated Operational Voltage:
277 V AC
Warranty:
18 months
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
0.98 in
Local Signalling:
trip indicator
Breaking Capacity:
65 kA 240 V AC || 65 kA 277 V AC || 100 kA 120 V AC || 65 kA 120/240 V AC
Electrical Connection:
lugs aluminium
Mercury Free:
Yes
Line Rated Current:
25 A
Number Of Spaces:
1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Height:
5.66 in
Device Short Name:
EJB
Rohs Exemption Information:
Yes
Product Or Component Type:
miniature circuit-breaker
Trip Unit Rating:
875-875 A
Module Type:
E-Frame
Depth:
4.05 in
Ambient Air Temperature For Operation:
40 °C
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Range Of Product:
125 A Frame EDB-EGB-EJB
Trip Unit Technology:
thermal-magnetic
Net Weight:
2 lb(US)
Number Of Spaces Required:
1
Holding Current:
270 A
Number Of Poles:
1
Brochure:
View
Catalog:
View
Datasheet:
View
$408.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 25A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose