Schneider Electric EJB24110 Miniature Circuit Breaker 480Y/277V 110A

(No reviews yet) Write a Review
SKU:
EJB24110
UPC:
785901634706
Condition:
New
Mounting Mode:
bolt-on
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Number Of Poles:
2
Line Rated Current:
110 A
[Ue] Rated Operational Voltage:
480Y/277 V AC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Connection:
lugs aluminium
Number Of Spaces Required:
2
Range Of Product:
125 A Frame EDB-EGB-EJB
Breaking Capacity:
65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
Product Destination:
NF panelboard
Height:
5.66 in
Trip Unit Rating:
2300-2300 A
Product Or Component Type:
miniature circuit-breaker
Rohs Exemption Information:
Yes
Breaking Capacity Code:
J
Ambient Air Temperature For Operation:
40 °C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Local Signalling:
trip indicator
Warranty:
18 months
Width:
1.96 in
Number Of Spaces:
2
Product Certifications:
cULus
Net Weight:
3 lb(US)
Device Short Name:
EJB
Protection Type:
short-circuit || overload
Holding Current:
1000 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Trip Unit Technology:
thermal-magnetic
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Module Type:
E-Frame
Depth:
4.05 in
$3,879.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 110A, 2 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. HACR rated.