Schneider Electric EJB26025 Miniature Circuit Breaker 600V 25A

(No reviews yet) Write a Review
SKU:
EJB26025
UPC:
7.85901E+11
Condition:
New
Circuit Breaker Application:
HACR rated
Mercury Free:
Yes
Net Weight:
3 lb(US)
Mounting Mode:
bolt-on
Product Or Component Type:
circuit-breaker
Rohs Exemption Information:
Yes
Breaking Capacity:
25 kA 600Y/347 V AC
Warranty:
18 months
Number Of Poles:
2
[Ue] Rated Operational Voltage:
600Y/347 V AC
Depth:
4.05 in
Module Type:
E-Frame
Awg Gauge:
AWG 12...AWG 6 aluminium || AWG 14...AWG 6 copper
Trip Unit Technology:
thermal-magnetic
Product Destination:
NF panelboard
Trip Unit Rating:
875-875 A
Breaking Capacity Code:
J
Local Signalling:
trip indicator
Product Certifications:
cULus
Protection Type:
short-circuit || overload
Tightening Torque:
3.4-3.4 N.m 2.5-16 mm² (AWG 14...AWG 6)
Holding Current:
270 A
Line Rated Current:
25 A
Number Of Spaces Required:
2
Width:
1.96 in
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
125 A Frame EDB-EGB-EJB
Electrical Connection:
lugs aluminium
Device Short Name:
EJB
Number Of Spaces:
2
Height:
5.66 in
Ambient Air Temperature For Operation:
40 °C
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
  • Schneider Electric EJB26025 Miniature Circuit Breaker 600V 25A
  • Schneider Electric EJB26025 Miniature Circuit Breaker 600V 25A
$1,552.50

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 25A, 2 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose