Schneider Electric EJB34070AABASA Miniature Circuit Breaker 480Y/277V 70A

(No reviews yet) Write a Review
SKU:
EJB34070AABASA
UPC:
3606486143155
Condition:
New
Rohs Exemption Information:
Yes
Mounting Mode:
bolt-on
Line Rated Current:
70 A
Product Or Component Type:
miniature circuit-breaker
Holding Current:
630 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity Code:
J
Protection Type:
short-circuit || overload
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
480Y/277 V AC
Ambient Air Temperature For Operation:
40 °C
Device Short Name:
EJB
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Height:
5.66 in
Depth:
4.05 in
Net Weight:
4 lb(US)
Product Destination:
NF panelboard
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Module Type:
E-Frame
Trip Unit Technology:
thermal-magnetic
Mercury Free:
Yes
Number Of Poles:
3
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Width:
3.92 in
Number Of Spaces:
4
Product Certifications:
cULus
Range Of Product:
125 A Frame EDB-EGB-EJB
Trip Unit Rating:
1800-1800 A
Circuit Breaker Application:
HACR rated
Local Signalling:
trip indicator
Number Of Spaces Required:
4
Device Composition:
auxiliary switch || shunt trip || alarm switch
Breaking Capacity:
65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
Electrical Connection:
lugs aluminium
$3,629.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 70A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch, alarm switch and a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
View AllClose