Schneider Electric EJB34080CA Miniature Circuit Breaker 480Y/277V 80A

(No reviews yet) Write a Review
SKU:
EJB34080CA
UPC:
3606486143179
Condition:
New
Number Of Poles:
3
Trip Unit Rating:
2300-2300 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Number Of Spaces:
3
Electrical Connection:
lugs aluminium
Rohs Exemption Information:
Yes
Width:
2.94 in
Breaking Capacity:
65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
Height:
5.66 in
Local Signalling:
trip indicator
Product Certifications:
cULus
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Device Short Name:
EJB
Net Weight:
4 lb(US)
Holding Current:
1000 A
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Range Of Product:
125 A Frame EDB-EGB-EJB
Circuit Breaker Application:
HACR rated
Product Destination:
NF panelboard
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Mounting Mode:
bolt-on
Ambient Air Temperature For Operation:
50 °C
Mercury Free:
Yes
Depth:
4.05 in
Breaking Capacity Code:
J
Module Type:
E-Frame
Trip Unit Technology:
thermal-magnetic
Number Of Spaces Required:
3
[Ue] Rated Operational Voltage:
480Y/277 V AC
Product Or Component Type:
miniature circuit-breaker
Protection Type:
overload || short-circuit
Line Rated Current:
80 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Catalog:
View
Datasheet:
View
$3,074.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 80A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 50 degrees C. HACR rated.
View AllClose