Schneider Electric EJB34125SA Miniature Circuit Breaker 480Y/277V 125A

(No reviews yet) Write a Review
SKU:
EJB34125SA
UPC:
785901649410
Condition:
New
[Ue] Rated Operational Voltage:
480Y/277 V AC
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Warranty:
18 months
Mercury Free:
Yes
Trip Unit Technology:
thermal-magnetic
Width:
3.92 in
Circuit Breaker Application:
HACR rated
Height:
5.66 in
Breaking Capacity:
65 kA 277 V AC || 100 kA 240 V AC || 65 kA 480Y/277 V AC || 100 kA 120 V AC || 100 kA 120/240 V AC
Range Of Product:
125 A Frame EDB-EGB-EJB
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Composition:
shunt trip
Number Of Poles:
3
Line Rated Current:
125 A
Eu Rohs Directive:
Compliant with Exemptions
Number Of Spaces:
4
Depth:
4.05 in
Device Short Name:
EJB
Holding Current:
1000 A
Ambient Air Temperature For Operation:
40 °C
Trip Unit Rating:
2300-2300 A
Breaking Capacity Code:
J
Number Of Spaces Required:
4
Electrical Connection:
lugs aluminium
Product Or Component Type:
miniature circuit-breaker
Protection Type:
short-circuit || overload
Product Certifications:
cULus
Net Weight:
4 lb(US)
Module Type:
E-Frame
Local Signalling:
trip indicator
Mounting Mode:
bolt-on
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Destination:
NF panelboard
$5,581.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 125A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
View AllClose