Schneider Electric EJB36035 Miniature Circuit Breaker 600V 35A

(No reviews yet) Write a Review
SKU:
EJB36035
UPC:
785901412434
Condition:
New
Product Certifications:
cULus
Depth:
4.05 in
Local Signalling:
trip indicator
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Trip Unit Rating:
1800-1800 A
Ambient Air Temperature For Operation:
40 °C
Module Type:
E-Frame
Holding Current:
630 A
Height:
5.66 in
Line Rated Current:
35 A
Range Of Product:
125 A Frame EDB-EGB-EJB
Breaking Capacity:
25 kA 600Y/347 V AC
Product Destination:
NF panelboard
Mercury Free:
Yes
Mounting Mode:
bolt-on
Number Of Poles:
3
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Width:
2.94 in
Circuit Breaker Application:
HACR rated
[Ue] Rated Operational Voltage:
600Y/347 V AC
Protection Type:
short-circuit || overload
Product Or Component Type:
circuit-breaker
Electrical Connection:
lugs aluminium
Breaking Capacity Code:
J
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Net Weight:
4 lb(US)
Number Of Spaces Required:
3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Trip Unit Technology:
thermal-magnetic
Number Of Spaces:
3
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Device Short Name:
EJB
Warranty:
18 months
Brochure:
View
Catalog:
View
Datasheet:
View
$1,809.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 35A, 3 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose