Schneider Electric

Schneider Electric GV2P14 Tesys Motor Circuit Breaker

(No reviews yet) Write a Review
SKU:
GV2P14
UPC:
3.38911E+12
Condition:
New
Range:
TeSys Deca
Network Frequency:
50/60 Hz IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Trip Unit Technology:
thermal-magnetic
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Fire Resistance:
960 °C IEC 60695-2-11
Motor Power Kw:
3-3 kW 400/415 V AC 50/60 Hz || 5-5 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 690 V AC 50/60 Hz
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Ik Degree Of Protection:
IK04
Ambient Air Temperature For Storage:
-40-80 °C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI2211002
Depth:
97 mm
Control Type:
rotary handle
Product Certifications:
CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Rated Duty:
continuous IEC 60947-4-1
Line Rated Current:
0.416666666666667
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Poles Description:
3P
Phase Failure Sensitivity:
yes IEC 60947-4-1
Mechanical Durability:
100000 cycles
Climatic Withstand:
IACS E10
Power Dissipation Per Pole:
2.5 W
Operating Altitude:
6561.68 ft (2000 m)
Device Application:
motor protection
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Magnetic Tripping Current:
138-138 A
Thermal Protection Adjustment Range:
6-10 A IEC 60947-4-1
Height:
89 mm
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
Product Or Component Type:
motor circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Network Type:
AC
Color:
dark grey
Ip Degree Of Protection:
IP20 IEC 60529
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Device Short Name:
GV2P
[Ith] Conventional Free Air Thermal Current:
10 A IEC 60947-4-1
Ambient Air Temperature For Operation:
-20-60 °C
Width:
45 mm
Product Name:
TeSys GV2 || TeSys Deca
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Warranty:
18 months
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Environmental Disclosure:
ENVPEP2211002
Tightening Torque:
1.7 N.m screw clamp terminal
Datasheet:
View
$233.00

Description

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 6 ampere to 10 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose