Schneider Electric GV2P22 Tesys Motor Circuit Breaker

(No reviews yet) Write a Review
SKU:
GV2P22
UPC:
3389110213539
Condition:
New
Motor Power Kw:
11-11 kW 400/415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz
Ambient Air Temperature For Storage:
-40-80 °C
Poles Description:
3P
Depth:
97 mm
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 50 % 400/415 V AC 50/60 Hz IEC 60947-2 || 75 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Product Certifications:
CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Width:
45 mm
[Ith] Conventional Free Air Thermal Current:
25 A IEC 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws)
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
Rated Duty:
continuous IEC 60947-4-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
motor protection
Product Or Component Type:
motor circuit breaker
Fire Resistance:
960 °C IEC 60695-2-11
Climatic Withstand:
IACS E10
Ik Degree Of Protection:
IK04
Environmental Disclosure:
ENVPEP2211002
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Device Short Name:
GV2P
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Height:
89 mm
Tightening Torque:
1.7 N.m screw clamp terminal
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
TeSys GV2 || TeSys Deca
Network Frequency:
50/60 Hz IEC 60947-4-1
Mechanical Durability:
100000 cycles
Color:
dark grey
Power Dissipation Per Pole:
2.5 W
Operating Altitude:
6561.68 ft (2000 m)
Ip Degree Of Protection:
IP20 IEC 60529
Range:
TeSys Deca
Circularity Profile:
ENVEOLI2211002
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Phase Failure Sensitivity:
yes IEC 60947-4-1
Magnetic Tripping Current:
327-327 A
Ambient Air Temperature For Operation:
-20-60 °C
Warranty:
18 months
Network Type:
AC
Line Rated Current:
25 A
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type:
rotary handle
Trip Unit Technology:
thermal-magnetic
Thermal Protection Adjustment Range:
20-25 A IEC 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Catalog:
View
Datasheet:
View
  • Schneider Electric GV2P22 Tesys Motor Circuit Breaker
  • Schneider Electric GV2P22 Tesys Motor Circuit Breaker
$278.00

Description

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2P controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 20 ampere to 25 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose