GV2RT20
UPC:
3389110520712
Condition:
New
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Ambient Air Temperature For Storage:
-40-80 °C
Suitability For Isolation:
yes IEC 60947-1 § 7-1-6
Breaking Capacity:
100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Depth:
78.5 mm
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
[Ith] Conventional Free Air Thermal Current:
18 A IEC 60947-4-1
Operating Altitude:
6561.68 ft (2000 m)
Climatic Withstand:
IACS E10
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
toggle
Thermal Protection Adjustment Range:
13-18 A IEC 60947-4-1
Device Application:
motor protection || transformer
Tightening Torque:
1.7 N.m screw clamp terminal
Height:
89 mm
Power Dissipation Per Pole:
2.5 W
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
motor circuit breaker
Width:
45 mm
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Trip Unit Technology:
thermal-magnetic
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz IEC 60947-4-1
Poles Description:
3P
Network Type:
AC
Product Certifications:
CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || UKCA
Line Rated Current:
18 A
Device Short Name:
GV2RT
Ambient Air Temperature For Operation:
-20-60 °C
Standards:
EN/IEC 60947-2 || EN/IEC 60947-4-1
Rated Duty:
continuous IEC 60947-4-1
Warranty:
18 months
Ip Degree Of Protection:
IP20 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Range:
TeSys Deca
Ik Degree Of Protection:
IK04
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Magnetic Tripping Current:
400-400 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Motor Power Kw:
4-4 kW 220/230 V AC 50/60 Hz motor protection high peak current || 7.5-7.5 kW 400/415 V AC 50/60 Hz motor protection high peak current || 7.5-7.5 kW 440 V AC 50/60 Hz motor protection high peak current || 9-9 kW 440 V AC 50/60 Hz motor protection hig
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Mechanical Durability:
100000 cycles
Circularity Profile:
ENVEOLI121004
Fire Resistance:
960 °C IEC 60695-2-11
Product Name:
TeSys GV2 || TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP121004
Rohs Exemption Information:
Yes
Datasheet:
View
$224.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for high starting current peak motor applications 7.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 13-18A, a magnetic tripping level at 20xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose