Schneider Electric GV3P18 Tesys Motor Cb Tho/Mag 12-18A Evlk
Schneider Electric
$404.00
GV3P18 is a TeSys GV motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 7.5kW@400V and high breaking capacity Icu 100kA. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. GV3P18 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 7.5kW@400V. It fulfills a thermal-magnetic protection with a thermal setting range 12-18A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. Compact, 55mm wide, for DIN-rail and panel mounting. Manual control with rotary knob for Start / Stop, padlockable. Possible mounting of auxiliary contacts front or side mounted (GVAE, GVAN, GVAD) for status and tripping signaling. For large industrial or building LV distribution networks thanks to a high 100kA breaking capacity. Power connections with EverLink BTR screw connectors providing constant tightening pressure. Can be associated with undervoltage or shunt tripping units (GVAU, GVAS) and power distribution busbars (GV3G).
- [Ith] Conventional Free Air Thermal Current:
- 18 A IEC 60947-4-1
- Depth:
- 136 mm
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Environmental Disclosure:
- ENVPEP060901
- Utilisation Category:
- AC-3 IEC 60947-4-1
- Rated Duty:
- continuous IEC 60947-4-1
- Trip Unit Technology:
- thermal-magnetic
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || ABS || DNV-GL || UKCA
- Line Rated Current:
- 18 A
- Ip Degree Of Protection:
- IP20 IEC 60529
- Product Name:
- TeSys GV3 || TeSys Deca
- Color:
- dark grey
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Magnetic Tripping Current:
- 252-252 A
- Eu Rohs Directive:
- Compliant with Exemptions
- Sustainable Offer Status:
- Green Premium product
- Electrical Durability:
- 50000 cycles AC-3 415 V In
- Power Dissipation Per Pole:
- 8 W
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
- Product Or Component Type:
- motor circuit breaker
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Climatic Withstand:
- IACS E10
- Device Short Name:
- GV3P
- Suitability For Isolation:
- yes IEC 60947-1
- Thermal Protection Adjustment Range:
- 12-18 A IEC 60947-4-1
- Device Application:
- motor protection
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Motor Power Kw:
- 7.5-7.5 kW 400/415 V AC 50/60 Hz || 9-9 kW 500 V AC 50/60 Hz || 15-15 kW 690 V AC 50/60 Hz
- Mechanical Robustness:
- shocks 15 Gn for 11 ms contactor open || shocks 30 Gn for 11 ms contactor closed || vibrations 4 Gn, 5...300 Hz
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- Ik Degree Of Protection:
- IK09 enclosure
- Height:
- 132 mm
- Operating Altitude:
- 9842.52 ft (3000 m)
- Mercury Free:
- Yes
- Ambient Air Temperature For Operation:
- -20-60 °C
- Control Type:
- rotary handle
- Net Weight:
- 0.96 kg
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Warranty:
- 18 months
- Poles Description:
- 3P
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 50 % 500 V AC 50/60 Hz IEC 60947-2 || 50 % 690 V AC 50/60 Hz IEC 60947-2
- Mechanical Durability:
- 50000 cycles
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Circularity Profile:
- ENVEOLI060901
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
- Tightening Torque:
- 5 N.m screw clamp terminal
- Width:
- 55 mm
- Range:
- TeSys Deca
- Ambient Air Temperature For Storage:
- -40-80 °C
- Network Type:
- AC
- Rohs Exemption Information:
- Yes
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View