GV3P25 is a TeSys GV motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 11kW@400V and high breaking capacity Icu 100kA. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. GV3P25 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 11kW@400V. It fulfills a thermal-magnetic protection with a thermal setting range 17-25A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. Compact, 55mm wide, for DIN-rail and panel mounting. Manual control with rotary knob for Start / Stop, padlockable. Possible mounting of auxiliary contacts front or side mounted (GVAE, GVAN, GVAD) for status and tripping signaling. For large industrial or building LV distribution networks thanks to a high 100kA breaking capacity. Power connections with EverLink BTR screw connectors providing constant tightening pressure. Can be associated with undervoltage or shunt tripping units (GVAU, GVAS) and power distribution busbars (GV3G).
- Mercury Free:
- Yes
- Breaking Capacity:
- 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 12 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- Width:
- 55 mm
- Color:
- dark grey
- Standards:
- EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
- Line Rated Current:
- 25 A
- Mechanical Robustness:
- shocks 15 Gn for 11 ms contactor open || shocks 30 Gn for 11 ms contactor closed || vibrations 4 Gn, 5...300 Hz
- Device Short Name:
- GV3P
- Electrical Durability:
- 50000 cycles AC-3 415 V In
- Thermal Protection Adjustment Range:
- 17-25 A IEC 60947-4-1
- Utilisation Category:
- AC-3 IEC 60947-4-1
- Ik Degree Of Protection:
- IK09 enclosure
- Climatic Withstand:
- IACS E10
- Eu Rohs Directive:
- Compliant with Exemptions
- Device Application:
- motor protection
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Environmental Disclosure:
- ENVPEP060901
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Rohs Exemption Information:
- Yes
- Poles Description:
- 3P
- [Ith] Conventional Free Air Thermal Current:
- 25 A IEC 60947-4-1
- Net Weight:
- 0.96 kg
- Control Type:
- rotary handle
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || ABS || DNV-GL || UKCA
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-2
- Motor Power Kw:
- 11-11 kW 400/415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 690 V AC 50/60 Hz
- Height:
- 132 mm
- Power Dissipation Per Pole:
- 8 W
- Network Frequency:
- 50/60 Hz IEC 60947-4-1
- Ambient Air Temperature For Operation:
- -20-60 °C
- Warranty:
- 18 months
- Rated Duty:
- continuous IEC 60947-4-1
- Fixing Mode:
- 35 mm symmetrical DIN rail clipped || panel screwed with 3 x M4 screws)
- Ip Degree Of Protection:
- IP20 IEC 60529
- Product Or Component Type:
- motor circuit breaker
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- [Ui] Rated Insulation Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Range:
- TeSys Deca
- Depth:
- 136 mm
- Ambient Air Temperature For Storage:
- -40-80 °C
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI060901
- Fire Resistance:
- 960 °C IEC 60695-2-11
- Operating Altitude:
- 9842.52 ft (3000 m)
- Mechanical Durability:
- 50000 cycles
- Trip Unit Technology:
- thermal-magnetic
- Product Name:
- TeSys GV3 || TeSys Deca
- Suitability For Isolation:
- yes IEC 60947-1
- Magnetic Tripping Current:
- 350-350 A
- Network Type:
- AC
- Tightening Torque:
- 5 N.m screw clamp terminal
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 50 % 500 V AC 50/60 Hz IEC 60947-2 || 50 % 690 V AC 50/60 Hz IEC 60947-2