Schneider Electric GV4PB115N Motbreakgv4Pbul489Th/Mag 115A 50Ka Elink

(No reviews yet) Write a Review
SKU:
GV4PB115N
UPC:
3606489868628
Condition:
New
Power Dissipation Per Pole:
4.6 W
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Product Or Component Type:
motor circuit breaker
Warranty:
18 months
Height:
171 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
toggle
Breaking Capacity:
65 kA SCCR 240 V AC 60 Hz UL 489 || 35 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 18 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947
Fire Resistance:
960 °C IEC 60695-2-11
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Trip Unit Technology:
electronic || thermal-magnetic
Maximum Operating Rate:
25 cyc/h
Ambient Air Temperature For Operation:
-25-70 °C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Suitability For Isolation:
yes IEC 60947-1
Ambient Air Temperature For Storage:
-50-85 °C
Product Name:
TeSys GV4 || TeSys Deca
Halogen Content Performance:
Halogen free plastic parts product
Device Short Name:
GV4PB
Color:
Gray RAL 7016)
Ik Degree Of Protection:
IK07 IEC 62262
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Rohs Exemption Information:
Yes
Climatic Withstand:
IACS E10
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Poles Description:
3P
Pollution Degree:
3
Range:
TeSys Deca
Depth:
116 mm
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Net Weight:
1.45 kg
Product Certifications:
IEC || UL || CSA
Magnetic Tripping Current:
1955-1955 A
Phase Failure Sensitivity:
yes IEC 60947-4-1
Line Rated Current:
115 A
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Range Of Product:
TeSys GV4
Pvc Free:
Yes
Mechanical Durability:
40000 cycles
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Circularity Profile:
ENVEOLI1704004EN
Device Application:
motor protection
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Sustainable Offer Status:
Green Premium product
Rated Duty:
continuous IEC 60947-4-1
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
IP40 IEC 60529
Width:
81 mm
Environmental Disclosure:
ENVPEP1704004EN
Operating Position:
any position
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Operating Altitude:
5000 m
Catalog:
View
Datasheet:
View
$551.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).