Schneider Electric GV4PB12N Motbreakgv4Pbul489Th/Mag 12.5 A50Kaelink

(No reviews yet) Write a Review
SKU:
GV4PB12N
UPC:
3606489868581
Condition:
New
Net Weight:
1.45 kg
Power Dissipation Per Pole:
4.6 W
Maximum Operating Rate:
25 cyc/h
Operating Altitude:
5000 m
Mercury Free:
Yes
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Product Name:
TeSys GV4 || TeSys Deca
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Phase Failure Sensitivity:
yes IEC 60947-4-1
Magnetic Tripping Current:
213-213 A
Device Short Name:
GV4PB
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Durability:
40000 cycles
Trip Unit Technology:
electronic || thermal-magnetic
Poles Description:
3P
Ambient Air Temperature For Storage:
-50-85 °C
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Fire Resistance:
960 °C IEC 60695-2-11
Range:
TeSys Deca
Warranty:
18 months
Halogen Content Performance:
Halogen free plastic parts product
Ik Degree Of Protection:
IK07 IEC 62262
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Ip Degree Of Protection:
IP40 IEC 60529
Rated Duty:
continuous IEC 60947-4-1
Range Of Product:
TeSys GV4
Device Application:
motor protection
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Pollution Degree:
3
Product Or Component Type:
motor circuit breaker
Depth:
116 mm
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Product Certifications:
IEC || UL || CSA
Eu Rohs Directive:
Compliant with Exemptions
Color:
Gray RAL 7016)
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Operating Position:
any position
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
-25-70 °C
Suitability For Isolation:
yes IEC 60947-1
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
65 kA SCCR 240 V AC 60 Hz UL 489 || 35 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 18 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
81 mm
Height:
171 mm
Line Rated Current:
12.5 A
Climatic Withstand:
IACS E10
Circularity Profile:
ENVEOLI1704004EN
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Environmental Disclosure:
ENVPEP1704004EN
Datasheet:
View
$492.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose