Schneider Electric GV4PB25N Motbreakgv4Pbul489Th/Mag 25A 50Ka Elink

(No reviews yet) Write a Review
SKU:
GV4PB25N
UPC:
3606489868598
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Net Weight:
1.45 kg
Trip Unit Technology:
electronic || thermal-magnetic
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pollution Degree:
3
Rated Duty:
continuous IEC 60947-4-1
Pvc Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Depth:
116 mm
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Ambient Air Temperature For Storage:
-50-85 °C
Range Of Product:
TeSys GV4
Control Type:
toggle
Climatic Withstand:
IACS E10
Suitability For Isolation:
yes IEC 60947-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Operating Altitude:
5000 m
Ambient Air Temperature For Operation:
-25-70 °C
Power Dissipation Per Pole:
4.6 W
Poles Description:
3P
Magnetic Tripping Current:
425-425 A
Device Application:
motor protection
Line Rated Current:
25 A
Product Name:
TeSys GV4 || TeSys Deca
Fire Resistance:
960 °C IEC 60695-2-11
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Sustainable Offer Status:
Green Premium product
Operating Position:
any position
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mercury Free:
Yes
Mechanical Durability:
40000 cycles
Height:
171 mm
Halogen Content Performance:
Halogen free plastic parts product
Ik Degree Of Protection:
IK07 IEC 62262
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Breaking Capacity:
65 kA SCCR 240 V AC 60 Hz UL 489 || 35 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 18 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 20000 cycles AC-3 440 V In
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Environmental Disclosure:
ENVPEP1704004EN
Color:
Gray RAL 7016)
Phase Failure Sensitivity:
yes IEC 60947-4-1
Circularity Profile:
ENVEOLI1704004EN
Device Short Name:
GV4PB
Range:
TeSys Deca
Ip Degree Of Protection:
IP40 IEC 60529
Product Or Component Type:
motor circuit breaker
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
Product Certifications:
IEC || UL || CSA
Maximum Operating Rate:
25 cyc/h
Width:
81 mm
Datasheet:
View
$508.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 10-25A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose