Schneider Electric GV4PB50N Motbreakgv4Pbul489Th/Mag 50A 50Ka Elink

(No reviews yet) Write a Review
SKU:
GV4PB50N
UPC:
3606489868604
Condition:
New
Width:
81 mm
Phase Failure Sensitivity:
yes IEC 60947-4-1
Suitability For Isolation:
yes IEC 60947-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Power Dissipation Per Pole:
4.6 W
Net Weight:
1.45 kg
Product Certifications:
IEC || UL || CSA
Pvc Free:
Yes
Ip Degree Of Protection:
IP40 IEC 60529
Color:
Gray RAL 7016)
Product Name:
TeSys GV4 || TeSys Deca
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2 || 600Y/347 V AC 60 Hz UL 489
Ambient Air Temperature For Operation:
-25-70 °C
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Mechanical Durability:
40000 cycles
Warranty:
18 months
Circularity Profile:
ENVEOLI1704004EN
Rated Duty:
continuous IEC 60947-4-1
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
Height:
171 mm
Poles Description:
3P
Ambient Air Temperature For Storage:
-50-85 °C
Trip Unit Technology:
electronic || thermal-magnetic
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Range:
TeSys Deca
Eu Rohs Directive:
Compliant with Exemptions
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Fire Resistance:
960 °C IEC 60695-2-11
Device Short Name:
GV4PB
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Magnetic Tripping Current:
850-850 A
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Operating Position:
any position
Product Or Component Type:
motor circuit breaker
Halogen Content Performance:
Halogen free plastic parts product
Device Application:
motor protection
Environmental Disclosure:
ENVPEP1704004EN
Operating Altitude:
5000 m
Climatic Withstand:
IACS E10
Control Type:
toggle
Line Rated Current:
50 A
Sustainable Offer Status:
Green Premium product
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Ik Degree Of Protection:
IK07 IEC 62262
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 525 V AC 50/60 Hz IEC 60947-2 || 25 % 660/690 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3
Range Of Product:
TeSys GV4
Depth:
116 mm
Breaking Capacity:
65 kA SCCR 240 V AC 60 Hz UL 489 || 35 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 18 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 100 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947
Maximum Operating Rate:
25 cyc/h
Datasheet:
View
$508.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
View AllClose