Schneider Electric HDA260402 Molded Case Circuit Breaker 600V 40A

(No reviews yet) Write a Review
SKU:
HDA260402
UPC:
785901632498
Condition:
New
Color:
Black
Mounting Height:
3 in
Trip Unit Technology:
thermal-magnetic
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Environmental Disclosure:
ENVPEP2206027EN
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Electrical Connection:
I-Line connection, line || lugs, load
Product Or Component Type:
circuit breaker
Utilisation Category:
category A
Continuous Current Rating:
0.8
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mercury Free:
Yes
Terminal Identifier:
AL150HD
Control Type:
toggle
Circularity Profile:
ENVEOLI2206027EN
Ambient Air Temperature For Operation:
-2-70 °C
Mounting Support:
bracket
Breaking Capacity Code:
D
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Rohs Exemption Information:
Yes
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Communication Interface:
Modbus || Ethernet
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Protected Poles Description:
2t
Product Certifications:
UL || CSA || NOM
Wire Stripping Length:
16 mm
Circuit Breaker Application:
HACR rated
Ip Degree Of Protection:
front cover IP40 IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Quantity Per Set:
1
Poles Description:
2P
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Warranty:
18 months
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Phase Connection:
AC
Local Signalling:
switched off (OFF) 1 trip indicator green)
Product Name:
PowerPact H
Quality Labels:
CE
Pollution Degree:
3 IEC 60947-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
163 mm
Sustainable Offer Status:
Green Premium product
Magnetic Tripping Current:
850-850 A
Net Weight:
2.2 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Application:
distribution
Magnetic Hold Current:
400 A
Line Rated Current:
40-40 A
Depth:
86 mm
Width:
104 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Mounting Mode:
I-Line bracket)
$899.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 40A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose