Schneider Electric HDA260404 Molded Case Circuit Breaker 600V 40A
Schneider Electric
$899.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 40A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Suitability For Isolation:
- yes IEC 60947-2
- Quality Labels:
- CE
- Breaking Capacity Code:
- D
- Electrical Connection:
- I-Line connection, line || lugs, load
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Utilisation Category:
- category A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Ambient Air Temperature For Operation:
- -2-70 °C
- Circularity Profile:
- ENVEOLI2206027EN
- Mercury Free:
- Yes
- Quantity Per Set:
- 1
- Eu Rohs Directive:
- Compliant with Exemptions
- Height:
- 163 mm
- Width:
- 104 mm
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Control Type:
- toggle
- Mounting Height:
- 3 in
- Protected Poles Description:
- 2t
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Mounting Support:
- bracket
- Pvc Free:
- Yes
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pollution Degree:
- 3 IEC 60947-1
- Product Or Component Type:
- circuit breaker
- Network Frequency:
- 50/60 Hz
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Terminal Identifier:
- AL150HD
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mounting Mode:
- I-Line bracket)
- Magnetic Hold Current:
- 400 A
- Warranty:
- 18 months
- Wire Stripping Length:
- 16 mm
- Net Weight:
- 2.2 kg
- Communication Interface:
- Modbus || Ethernet
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Product Certifications:
- UL || CSA || NOM
- Line Rated Current:
- 40-40 A
- Magnetic Tripping Current:
- 850-850 A
- Device Application:
- distribution
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Poles Description:
- 2P
- Sustainable Offer Status:
- Green Premium product
- Product Name:
- PowerPact H
- Depth:
- 86 mm
- Range:
- PowerPact
- Environmental Disclosure:
- ENVPEP2206027EN
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Rohs Exemption Information:
- Yes
- Continuous Current Rating:
- 0.8
- Trip Unit Technology:
- thermal-magnetic
- Color:
- Black
- Phase Connection:
- BC
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Circuit Breaker Application:
- HACR rated
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View