Schneider Electric HDA261004 Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HDA261004
UPC:
785901754350
Condition:
New
Terminal Identifier:
AL150HD
Magnetic Hold Current:
900 A
Eu Rohs Directive:
Compliant with Exemptions
Quality Labels:
CE
Phase Connection:
BC
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Height:
163 mm
Local Signalling:
switched off (OFF) 1 trip indicator green)
Sustainable Offer Status:
Green Premium product
Poles Description:
2P
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Mercury Free:
Yes
Product Name:
PowerPact H
Magnetic Tripping Current:
1700-1700 A
Environmental Disclosure:
ENVPEP2206027EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Color:
Black
Quantity Per Set:
1
Utilisation Category:
category A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Operation:
-2-70 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Wire Stripping Length:
16 mm
Net Weight:
2.2 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
distribution
Warranty:
18 months
Electrical Connection:
I-Line connection, line || lugs, load
Protected Poles Description:
2t
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Breaking Capacity Code:
D
Mounting Height:
3 in
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Product Certifications:
UL || CSA || NOM
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Width:
104 mm
Line Rated Current:
100-100 A
Pvc Free:
Yes
Control Type:
toggle
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Depth:
86 mm
Trip Unit Technology:
thermal-magnetic
Mounting Support:
bracket
Communication Interface:
Modbus || Ethernet
Product Or Component Type:
circuit breaker
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Pollution Degree:
3 IEC 60947-1
Circularity Profile:
ENVEOLI2206027EN
Ambient Air Temperature For Storage:
-50-85 °C
Ip Degree Of Protection:
front cover IP40 IEC 60529
Rohs Exemption Information:
Yes
Mounting Mode:
I-Line bracket)
$1,088.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.