Schneider Electric HDA36020 Molded Case Circuit Breaker 600V 20A
Schneider Electric
$1,124.00
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 20A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Mounting Height:
- 4.5 in
- Trip Unit Technology:
- thermal-magnetic
- Electrical Connection:
- I-Line connection, line || lugs, load
- Device Application:
- distribution
- Product Or Component Type:
- circuit breaker
- Phase Connection:
- ABC
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Line Rated Current:
- 20-20 A
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity Code:
- D
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Color:
- Black
- Circularity Profile:
- ENVEOLI2206027EN
- Mercury Free:
- Yes
- Quantity Per Set:
- 1
- Circuit Breaker Application:
- HACR rated
- Magnetic Tripping Current:
- 750-750 A
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Wire Stripping Length:
- 16 mm
- Eu Rohs Directive:
- Compliant with Exemptions
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Product Certifications:
- UL || CSA || NOM
- Magnetic Hold Current:
- 350 A
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mounting Support:
- bracket
- Width:
- 104 mm
- Mounting Mode:
- I-Line bracket)
- Protected Poles Description:
- 3t
- Pollution Degree:
- 3 IEC 60947-1
- Product Name:
- PowerPact H
- Quality Labels:
- CE
- Poles Description:
- 3P
- Continuous Current Rating:
- 0.8
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Pvc Free:
- Yes
- Range:
- PowerPact
- Depth:
- 86 mm
- Warranty:
- 18 months
- Communication Interface:
- Modbus || Ethernet
- Control Type:
- toggle
- Environmental Disclosure:
- ENVPEP2206027EN
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Net Weight:
- 2.2 kg
- Height:
- 163 mm
- Utilisation Category:
- category A
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Rohs Exemption Information:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Terminal Identifier:
- AL150HD
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Ambient Air Temperature For Operation:
- -2-70 °C
- Ambient Air Temperature For Storage:
- -50-85 °C
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View