Schneider Electric HDA36050SA Molded Case Circuit Breaker 600V 50A
Schneider Electric
$4,142.25
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 50A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Net Weight:
- 2.2 kg
- Quantity Per Set:
- 1
- Electrical Connection:
- I-Line connection, line || lugs, load
- Magnetic Hold Current:
- 400 A
- Control Type:
- toggle
- Eu Rohs Directive:
- Compliant
- Terminal Identifier:
- AL150HD
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Product Name:
- PowerPact H
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Circuit Breaker Application:
- HACR rated
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Range:
- PowerPact
- Ambient Air Temperature For Storage:
- -50-85 °C
- Pollution Degree:
- 3 IEC 60947-1
- Warranty:
- 18 months
- Utilisation Category:
- category A
- Suitability For Isolation:
- yes IEC 60947-2
- Depth:
- 86 mm
- Mounting Support:
- bracket
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Pvc Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Height:
- 163 mm
- Trip Unit Technology:
- thermal-magnetic
- Device Application:
- distribution
- Product Or Component Type:
- circuit breaker
- Poles Description:
- 3P
- Color:
- Black
- Line Rated Current:
- 50-50 A
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Magnetic Tripping Current:
- 850-850 A
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mercury Free:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Environmental Disclosure:
- ENVPEP1311006EN
- Breaking Capacity Code:
- D
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Continuous Current Rating:
- 0.8
- Mounting Height:
- 4.5 in
- Phase Connection:
- ABC
- Protected Poles Description:
- 3t
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Wire Stripping Length:
- 16 mm
- Width:
- 104 mm
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Network Frequency:
- 50/60 Hz
- Ambient Air Temperature For Operation:
- -2-70 °C
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Mounting Mode:
- I-Line bracket)
- Rohs Exemption Information:
- Yes
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Communication Interface:
- Modbus || Ethernet
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Circularity Profile:
- ENVEOLI1311006EN
- Quality Labels:
- CE
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View