Schneider Electric HDL26020C Molded Case Circuit Breaker 600V 20A

(No reviews yet) Write a Review
SKU:
HDL26020C
UPC:
785901872085
Condition:
New
Device Application:
distribution
Depth:
86 mm
Range:
PowerPact
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Sustainable Offer Status:
Green Premium product
Product Name:
PowerPact H
Network Frequency:
50/60 Hz
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Net Weight:
2.2 kg
Ambient Air Temperature For Operation:
-2-70 °C
Ambient Air Temperature For Storage:
-50-85 °C
Communication Interface:
Modbus || Ethernet
Terminal Identifier:
AL150HD
Control Type:
toggle
Height:
163 mm
Environmental Disclosure:
ENVPEP1311006EN
Magnetic Tripping Current:
750-750 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Width:
104 mm
Breaking Capacity Code:
D
Eu Rohs Directive:
Compliant
Quality Labels:
CE
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Magnetic Hold Current:
350 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pollution Degree:
3 IEC 60947-1
Color:
Black
Poles Description:
2P
Ip Degree Of Protection:
front cover IP40 IEC 60529
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Wire Stripping Length:
16 mm
Mercury Free:
Yes
Product Or Component Type:
circuit breaker
Line Rated Current:
20-20 A
Circuit Breaker Application:
HACR rated
Circularity Profile:
ENVEOLI1311006EN
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Quantity Per Set:
1
Utilisation Category:
category A
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Continuous Current Rating:
1
Warranty:
18 months
Mounting Support:
lug
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Local Signalling:
switched off (OFF) 1 trip indicator green)
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Product Certifications:
UL || CSA || NOM
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Protected Poles Description:
2t
Mounting Mode:
unit mount lug)
Electrical Connection:
lugs, line || lugs, load
$2,349.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 20A, 2 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose