Schneider Electric HDL36060U31X Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HDL36060U31X
UPC:
785901230472
Condition:
New
Product Name:
PowerPact H
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Mercury Free:
Yes
Width:
104 mm
Continuous Current Rating:
0.8
Line Rated Current:
60-60 A
Mounting Mode:
unit mount lug)
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
-2-70 °C
Wire Stripping Length:
16 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Circularity Profile:
ENVEOLI2206028EN
Pvc Free:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 3.2, LI
Terminal Identifier:
AL150HD
Control Type:
toggle
Rohs Exemption Information:
Yes
Communication Interface:
Modbus || Ethernet
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Warranty:
18 months
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Quality Labels:
CE
Mounting Support:
lug
Color:
Black
Poles Description:
3P
Quantity Per Set:
1
Breaking Capacity Code:
D
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Network Frequency:
50/60 Hz
Environmental Disclosure:
ENVPEP2206028EN
Trip Unit Name:
MicroLogic 3.2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Range:
PowerPact
Device Application:
distribution
Product Certifications:
UL || CSA || NOM
Depth:
86 mm
Height:
163 mm
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pollution Degree:
3 IEC 60947-1
Electrical Connection:
lugs, line || lugs, load
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Product Or Component Type:
circuit breaker
Protected Poles Description:
3t
Net Weight:
2.2 kg
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
  • Schneider Electric HDL36060U31X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HDL36060U31X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HDL36060U31X Molded Case Circuit Breaker 600V 60A
$1,247.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose