- Pollution Degree:
- 3 IEC 60947-1
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Line Rated Current:
- 70-70 A
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Color:
- Black
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Product Certifications:
- UL || CSA || NOM
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Rohs Exemption Information:
- Yes
- Depth:
- 86 mm
- Breaking Capacity Code:
- D
- Range:
- PowerPact
- Magnetic Hold Current:
- 800 A
- Height:
- 163 mm
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Suitability For Isolation:
- yes IEC 60947-2
- Terminal Identifier:
- AL150HD
- Mercury Free:
- Yes
- Control Type:
- toggle
- Mounting Support:
- lug
- Eu Rohs Directive:
- Compliant with Exemptions
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Circularity Profile:
- ENVEOLI2206027EN
- Continuous Current Rating:
- 0.8
- Electrical Connection:
- lugs, line || lugs, load
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Mounting Mode:
- unit mount lug)
- Trip Unit Technology:
- thermal-magnetic
- Device Application:
- distribution
- Circuit Breaker Application:
- HACR rated
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Magnetic Tripping Current:
- 1450-1450 A
- Quantity Per Set:
- 1
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Poles Description:
- 3P
- Quality Labels:
- CE
- Wire Stripping Length:
- 16 mm
- Network Frequency:
- 50/60 Hz
- Pvc Free:
- Yes
- Utilisation Category:
- category A
- Product Name:
- PowerPact H
- Protected Poles Description:
- 3t
- Width:
- 104 mm
- Sustainable Offer Status:
- Green Premium product
- Product Or Component Type:
- circuit breaker
- Net Weight:
- 2.2 kg
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Communication Interface:
- Modbus || Ethernet
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Environmental Disclosure:
- ENVPEP2206027EN
- QN-QUOTE-REQUEST:
- true