Schneider Electric HDL36080SA Molded Case Circuit Breaker 600V 80A

(No reviews yet) Write a Review
SKU:
HDL36080SA
UPC:
785901930662
Condition:
New
Net Weight:
2.2 kg
Protected Poles Description:
3t
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Width:
104 mm
Line Rated Current:
80-80 A
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Continuous Current Rating:
0.8
Mounting Mode:
unit mount lug)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Device Application:
distribution
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
Mercury Free:
Yes
Mounting Support:
lug
Rohs Exemption Information:
Yes
Product Certifications:
UL || CSA || NOM
Control Type:
toggle
Trip Unit Technology:
thermal-magnetic
Color:
Black
Network Frequency:
50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Depth:
86 mm
Suitability For Isolation:
yes IEC 60947-2
Wire Stripping Length:
16 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity Code:
D
Communication Interface:
Modbus || Ethernet
Quantity Per Set:
1
Pollution Degree:
3 IEC 60947-1
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Breaking Capacity:
25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
Warranty:
18 months
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Electrical Connection:
lugs, line || lugs, load
Pvc Free:
Yes
Circularity Profile:
ENVEOLI2206027EN
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Terminal Identifier:
AL150HD
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Environmental Disclosure:
ENVPEP2206027EN
Magnetic Hold Current:
800 A
[Ics] Rated Service Breaking Capacity:
25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Magnetic Tripping Current:
1450-1450 A
Product Name:
PowerPact H
Local Signalling:
switched off (OFF) 1 trip indicator green)
Range:
PowerPact
Height:
163 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quality Labels:
CE
  • Schneider Electric HDL36080SA Molded Case Circuit Breaker 600V 80A
  • Schneider Electric HDL36080SA Molded Case Circuit Breaker 600V 80A
  • Schneider Electric HDL36080SA Molded Case Circuit Breaker 600V 80A
$2,045.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 80A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose