Schneider Electric HDL36100CU31X Molded Case Circuit Breaker 600V 100A
Schneider Electric
$2,602.50
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2 trip unit and an LI function with a breaking capacity of 14kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 14kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Quality Labels:
- CE
- Product Name:
- PowerPact H
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Product Certifications:
- UL || CSA || NOM
- Circuit Breaker Application:
- HACR rated
- Local Signalling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Control Type:
- toggle
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Depth:
- 86 mm
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Quantity Per Set:
- 1
- Electrical Connection:
- lugs, line || lugs, load
- Ambient Air Temperature For Storage:
- -50-85 °C
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Wire Stripping Length:
- 16 mm
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Mounting Support:
- lug
- Net Weight:
- 2.2 kg
- Eu Rohs Directive:
- Compliant with Exemptions
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Ambient Air Temperature For Operation:
- -2-70 °C
- Protected Poles Description:
- 3t
- Pvc Free:
- Yes
- Line Rated Current:
- 100-100 A
- Continuous Current Rating:
- 1
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Device Application:
- distribution
- Width:
- 104 mm
- Environmental Disclosure:
- ENVPEP2206028EN
- Poles Description:
- 3P
- Mounting Mode:
- unit mount lug)
- Sustainable Offer Status:
- Green Premium product
- Network Frequency:
- 50/60 Hz
- Color:
- Black
- Height:
- 163 mm
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.2, LI
- Trip Unit Name:
- MicroLogic 3.2
- Communication Interface:
- Modbus || Ethernet
- Range:
- PowerPact
- Utilisation Category:
- category A
- Rohs Exemption Information:
- Yes
- Circularity Profile:
- ENVEOLI2206028EN
- Breaking Capacity Code:
- D
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Warranty:
- 18 months
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Terminal Identifier:
- AL150HD
- Pollution Degree:
- 3 IEC 60947-1
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Mercury Free:
- Yes