Schneider Electric HGA260352 Molded Case Circuit Breaker 600V 35A

(No reviews yet) Write a Review
SKU:
HGA260352
UPC:
7.85902E+11
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-2-70 °C
Protected Poles Description:
2t
Mounting Height:
3 in
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Magnetic Hold Current:
400 A
Height:
163 mm
Utilisation Category:
category A
Phase Connection:
AC
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Magnetic Tripping Current:
850-850 A
Quality Labels:
CE
Eu Rohs Directive:
Compliant
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
2.2 kg
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Wire Stripping Length:
16 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85 °C
Depth:
86 mm
Environmental Disclosure:
ENVPEP1311006EN
Line Rated Current:
35-35 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
Product Name:
PowerPact H
Sustainable Offer Status:
Green Premium product
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
2P
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Continuous Current Rating:
0.8
Ip Degree Of Protection:
front cover IP40 IEC 60529
Control Type:
toggle
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Width:
104 mm
Range:
PowerPact
Circularity Profile:
ENVEOLI1311006EN
Pollution Degree:
3 IEC 60947-1
Electrical Connection:
I-Line connection, line || lugs, load
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Network Frequency:
50/60 Hz
Device Application:
distribution
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Color:
Black
Mounting Support:
bracket
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Terminal Identifier:
AL150HD
Mounting Mode:
I-Line bracket)
Pvc Free:
Yes
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Warranty:
18 months
Quantity Per Set:
1
Communication Interface:
Modbus || Ethernet
Product Certifications:
UL || CSA || NOM
Breaking Capacity Code:
G
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA260352 Molded Case Circuit Breaker 600V 35A
  • Schneider Electric HGA260352 Molded Case Circuit Breaker 600V 35A
$2,007.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 35A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose