Schneider Electric HGA260452 Molded Case Circuit Breaker 600V 45A

(No reviews yet) Write a Review
SKU:
HGA260452
UPC:
7.85902E+11
Condition:
New
Line Rated Current:
45-45 A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Local Signalling:
switched off (OFF) 1 trip indicator green)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Environmental Disclosure:
ENVPEP2206027EN
Magnetic Hold Current:
400 A
Device Application:
distribution
Protected Poles Description:
2t
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Terminal Identifier:
AL150HD
Poles Description:
2P
Product Or Component Type:
circuit breaker
Breaking Capacity Code:
G
Circuit Breaker Application:
HACR rated
Product Name:
PowerPact H
Color:
Black
Mounting Height:
3 in
Range:
PowerPact
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Circularity Profile:
ENVEOLI2206027EN
Pollution Degree:
3 IEC 60947-1
Utilisation Category:
category A
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Height:
163 mm
Ambient Air Temperature For Operation:
-2-70 °C
Electrical Connection:
I-Line connection, line || lugs, load
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Depth:
86 mm
Eu Rohs Directive:
Compliant with Exemptions
Mounting Support:
bracket
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Communication Interface:
Modbus || Ethernet
Warranty:
18 months
Quantity Per Set:
1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Mercury Free:
Yes
Wire Stripping Length:
16 mm
Control Type:
toggle
Product Certifications:
UL || CSA || NOM
Width:
104 mm
Phase Connection:
AC
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Sustainable Offer Status:
Green Premium product
Magnetic Tripping Current:
850-850 A
Trip Unit Technology:
thermal-magnetic
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Net Weight:
2.2 kg
Quality Labels:
CE
Mounting Mode:
I-Line bracket)
Continuous Current Rating:
0.8
  • Schneider Electric HGA260452 Molded Case Circuit Breaker 600V 45A
  • Schneider Electric HGA260452 Molded Case Circuit Breaker 600V 45A
$2,007.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 45A, 2 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose