- Width:
- 104 mm
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Utilisation Category:
- category A
- Depth:
- 86 mm
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Pvc Free:
- Yes
- Phase Connection:
- ABC
- Mounting Height:
- 4.5 in
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Ambient Air Temperature For Operation:
- -2-70 °C
- Range:
- PowerPact
- Mounting Support:
- bracket
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Continuous Current Rating:
- 0.8
- Product Or Component Type:
- circuit breaker
- Mounting Mode:
- I-Line bracket)
- Pollution Degree:
- 3 IEC 60947-1
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Breaking Capacity Code:
- G
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Wire Stripping Length:
- 16 mm
- Magnetic Hold Current:
- 400 A
- Warranty:
- 18 months
- Quality Labels:
- CE
- Rohs Exemption Information:
- Yes
- Poles Description:
- 3P
- Circularity Profile:
- ENVEOLI2206027EN
- Network Frequency:
- 50/60 Hz
- Product Certifications:
- UL || CSA || NOM
- Line Rated Current:
- 50-50 A
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Magnetic Tripping Current:
- 850-850 A
- Color:
- Black
- Device Application:
- distribution
- Mercury Free:
- Yes
- Protected Poles Description:
- 3t
- Quantity Per Set:
- 1
- Terminal Identifier:
- AL150HD
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Height:
- 163 mm
- Product Name:
- PowerPact H
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Trip Unit Technology:
- thermal-magnetic
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- Environmental Disclosure:
- ENVPEP2206027EN
- Suitability For Isolation:
- yes IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Ambient Air Temperature For Storage:
- -50-85 °C
- Communication Interface:
- Modbus || Ethernet
- Circuit Breaker Application:
- HACR rated
- Eu Rohs Directive:
- Compliant with Exemptions
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Control Type:
- toggle
- Electrical Connection:
- I-Line connection, line || lugs, load
- Net Weight:
- 2.2 kg