Schneider Electric HGA36050 Molded Case Circuit Breaker 600V 50A

(No reviews yet) Write a Review
SKU:
HGA36050
UPC:
785901795025
Condition:
New
Width:
104 mm
Local Signalling:
switched off (OFF) 1 trip indicator green)
Utilisation Category:
category A
Depth:
86 mm
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Pvc Free:
Yes
Phase Connection:
ABC
Mounting Height:
4.5 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ambient Air Temperature For Operation:
-2-70 °C
Range:
PowerPact
Mounting Support:
bracket
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Continuous Current Rating:
0.8
Product Or Component Type:
circuit breaker
Mounting Mode:
I-Line bracket)
Pollution Degree:
3 IEC 60947-1
Ip Degree Of Protection:
front cover IP40 IEC 60529
Breaking Capacity Code:
G
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Wire Stripping Length:
16 mm
Magnetic Hold Current:
400 A
Warranty:
18 months
Quality Labels:
CE
Rohs Exemption Information:
Yes
Poles Description:
3P
Circularity Profile:
ENVEOLI2206027EN
Network Frequency:
50/60 Hz
Product Certifications:
UL || CSA || NOM
Line Rated Current:
50-50 A
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Magnetic Tripping Current:
850-850 A
Color:
Black
Device Application:
distribution
Mercury Free:
Yes
Protected Poles Description:
3t
Quantity Per Set:
1
Terminal Identifier:
AL150HD
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Height:
163 mm
Product Name:
PowerPact H
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Technology:
thermal-magnetic
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP2206027EN
Suitability For Isolation:
yes IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Ambient Air Temperature For Storage:
-50-85 °C
Communication Interface:
Modbus || Ethernet
Circuit Breaker Application:
HACR rated
Eu Rohs Directive:
Compliant with Exemptions
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Control Type:
toggle
Electrical Connection:
I-Line connection, line || lugs, load
Net Weight:
2.2 kg
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA36050 Molded Case Circuit Breaker 600V 50A
  • Schneider Electric HGA36050 Molded Case Circuit Breaker 600V 50A
  • Schneider Electric HGA36050 Molded Case Circuit Breaker 600V 50A
$1,575.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 50A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose