Schneider Electric HGA36060U44X Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HGA36060U44X
UPC:
7.85902E+11
Condition:
New
Color:
Black
Line Rated Current:
60-60 A
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Or Component Type:
circuit breaker
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Communication Interface:
Modbus || Ethernet
Terminal Identifier:
AL150HD
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Product Certifications:
UL || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Utilisation Category:
category A
Electrical Connection:
I-Line connection, line || lugs, load
Product Name:
PowerPact H
Phase Connection:
ABC
Mounting Mode:
I-Line bracket)
Trip Unit Name:
MicroLogic 6.2 A
Circuit Breaker Application:
HACR rated
Width:
104 mm
Mounting Height:
4.5 in
Wire Stripping Length:
16 mm
Sustainable Offer Status:
Green Premium product
Range:
PowerPact
Height:
163 mm
Quality Labels:
CE
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.2 A, LSIG
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Mercury Free:
Yes
Depth:
86 mm
Protected Poles Description:
3t
Rohs Exemption Information:
Yes
Device Application:
distribution
Ambient Air Temperature For Storage:
-50-85 °C
Network Frequency:
50/60 Hz
Poles Description:
3P
Breaking Capacity Code:
G
Suitability For Isolation:
yes IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Warranty:
18 months
Quantity Per Set:
1
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Circularity Profile:
ENVEOLI2206028EN
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Mounting Support:
bracket
Environmental Disclosure:
ENVPEP2206028EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Ip Degree Of Protection:
front cover IP40 IEC 60529
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Control Type:
toggle
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
2.2 kg
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Continuous Current Rating:
0.8
  • Schneider Electric HGA36060U44X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HGA36060U44X Molded Case Circuit Breaker 600V 60A
$3,330.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Ammeter with a 6.2A trip unit and an LSIG function with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose