Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
Terminal Identifier:
AL150HD
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Line Rated Current:
70-70 A
Continuous Current Rating:
0.8
Product Name:
PowerPact H
Depth:
86 mm
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Quality Labels:
CE
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Sustainable Offer Status:
Green Premium product
Trip Unit Technology:
thermal-magnetic
Suitability For Isolation:
yes IEC 60947-2
Utilisation Category:
category A
Magnetic Hold Current:
800 A
Phase Connection:
ABC
Circuit Breaker Application:
HACR rated
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Breaking Capacity Code:
G
Mounting Support:
bracket
Pollution Degree:
3 IEC 60947-1
Net Weight:
2.2 kg
Magnetic Tripping Current:
1450-1450 A
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Warranty:
18 months
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Certifications:
UL || CSA || NOM
Device Application:
distribution
Electrical Connection:
I-Line connection, line || lugs, load
Wire Stripping Length:
16 mm
Mounting Mode:
I-Line bracket)
Rohs Exemption Information:
Yes
Height:
163 mm
Ambient Air Temperature For Storage:
-50-85 °C
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Circularity Profile:
ENVEOLI2206027EN
Eu Rohs Directive:
Compliant with Exemptions
Mounting Height:
4.5 in
Product Or Component Type:
circuit breaker
Width:
104 mm
Pvc Free:
Yes
Mercury Free:
Yes
Color:
Black
Range:
PowerPact
Local Signalling:
switched off (OFF) 1 trip indicator green)
Communication Interface:
Modbus || Ethernet
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Protected Poles Description:
3t
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Poles Description:
3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Control Type:
toggle
Environmental Disclosure:
ENVPEP2206027EN
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HGA36070 Molded Case Circuit Breaker 600V 70A
  • Schneider Electric HGA36070 Molded Case Circuit Breaker 600V 70A
  • Schneider Electric HGA36070 Molded Case Circuit Breaker 600V 70A
$1,772.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 70A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose