Schneider Electric HGL36030C Molded Case Circuit Breaker 600V 30A
Schneider Electric
$2,686.50
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 30A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Poles Description:
- 3P
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pvc Free:
- Yes
- Quantity Per Set:
- 1
- Quality Labels:
- CE
- Warranty:
- 18 months
- Control Type:
- toggle
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Compliant with Exemptions
- Circuit Breaker Application:
- HACR rated
- Utilisation Category:
- category A
- Protected Poles Description:
- 3t
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Ambient Air Temperature For Storage:
- -50-85 °C
- Color:
- Black
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Product Certifications:
- UL || CSA || NOM
- Product Or Component Type:
- circuit breaker
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Circularity Profile:
- ENVEOLI2206027EN
- Suitability For Isolation:
- yes IEC 60947-2
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Net Weight:
- 2.2 kg
- Rohs Exemption Information:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Height:
- 163 mm
- Mounting Support:
- lug
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Electrical Connection:
- lugs, line || lugs, load
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Range:
- PowerPact
- Device Application:
- distribution
- Communication Interface:
- Modbus || Ethernet
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Terminal Identifier:
- AL150HD
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Magnetic Hold Current:
- 350 A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Mercury Free:
- Yes
- Network Frequency:
- 50/60 Hz
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Mounting Mode:
- unit mount lug)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Trip Unit Technology:
- thermal-magnetic
- Depth:
- 86 mm
- Pollution Degree:
- 3 IEC 60947-1
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Environmental Disclosure:
- ENVPEP2206027EN
- Line Rated Current:
- 30-30 A
- Product Name:
- PowerPact H
- Continuous Current Rating:
- 1
- Wire Stripping Length:
- 16 mm
- Breaking Capacity Code:
- G
- Width:
- 104 mm
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Magnetic Tripping Current:
- 750-750 A
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View