Schneider Electric HGL36050T Molded Case Circuit Breaker 600V 50A

(No reviews yet) Write a Review
SKU:
HGL36050T
UPC:
785901474104
Condition:
New
Quantity Per Set:
1
Color:
Black
Pvc Free:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Poles Description:
3P
Circuit Breaker Application:
HACR rated
Mounting Mode:
unit mount lug)
Circularity Profile:
ENVEOLI2206027EN
Magnetic Tripping Current:
850-850 A
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
lugs, line || lugs, load
Quality Labels:
CE
Range:
PowerPact
Local Signalling:
switched off (OFF) 1 trip indicator green)
Control Type:
toggle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Certifications:
UL || CSA || NOM
Continuous Current Rating:
0.8
Wire Stripping Length:
16 mm
Magnetic Hold Current:
400 A
Line Rated Current:
50-50 A
Communication Interface:
Modbus || Ethernet
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Ambient Air Temperature For Storage:
-50-85 °C
Product Name:
PowerPact H
Mercury Free:
Yes
Net Weight:
2.2 kg
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Environmental Disclosure:
ENVPEP2206027EN
Protected Poles Description:
3t
Depth:
86 mm
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Width:
104 mm
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Mounting Support:
lug
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Device Application:
distribution
Warranty:
18 months
Rohs Exemption Information:
Yes
Installed Device:
trip unit field installable
Product Or Component Type:
circuit breaker
Terminal Identifier:
AL150HD
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Height:
163 mm
Breaking Capacity Code:
G
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
front cover IP40 IEC 60529
Utilisation Category:
category A
Suitability For Isolation:
yes IEC 60947-2
Network Frequency:
50/60 Hz
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$1,493.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 50A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit allows field-interchangeable trip units. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.