Schneider Electric HGL36100AASA Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HGL36100AASA
UPC:
785901496199
Condition:
New
Electrical Connection:
lugs, line || lugs, load
Pvc Free:
Yes
Breaking Capacity Code:
G
Quantity Per Set:
1
Width:
104 mm
Suitability For Isolation:
yes IEC 60947-2
Quality Labels:
CE
Magnetic Tripping Current:
1700-1700 A
Circuit Breaker Application:
HACR rated
Height:
163 mm
Environmental Disclosure:
ENVPEP1311006EN
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
Control Type:
toggle
Protected Poles Description:
3t
Poles Description:
3P
Mounting Support:
lug
Depth:
86 mm
Terminal Identifier:
AL150HD
Color:
Black
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Local Signalling:
switched off (OFF) 1 trip indicator green)
Mercury Free:
Yes
Communication Interface:
Modbus || Ethernet
Ambient Air Temperature For Storage:
-50-85 °C
Product Certifications:
UL || CSA || NOM
Mounting Mode:
unit mount lug)
Net Weight:
2.2 kg
Product Name:
PowerPact H
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Utilisation Category:
category A
Eu Rohs Directive:
Compliant
Ip Degree Of Protection:
front cover IP40 IEC 60529
Ambient Air Temperature For Operation:
-2-70 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
100-100 A
Circularity Profile:
ENVEOLI1311006EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Magnetic Hold Current:
900 A
Range:
PowerPact
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Wire Stripping Length:
16 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
Trip Unit Technology:
thermal-magnetic
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Accessory / Separate Part Type:
auxiliary switch 24 V AC/DC 1 NO + 1 NC cover frame
Continuous Current Rating:
0.8
Product Or Component Type:
circuit breaker
Device Application:
distribution
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Rohs Exemption Information:
Yes
Brochure:
View
Catalog:
View
Datasheet:
View
$4,072.50

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 1A/1B auxiliary switch and 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose