Schneider Electric HGL36100SA Molded Case Circuit Breaker 600V 100A
Schneider Electric
$2,418.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 100A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Utilisation Category:
- category A
- Poles Description:
- 3P
- Protected Poles Description:
- 3t
- Mounting Mode:
- unit mount lug)
- Mounting Support:
- lug
- Trip Unit Technology:
- thermal-magnetic
- Ambient Air Temperature For Storage:
- -50-85 °C
- Terminal Identifier:
- AL150HD
- Height:
- 163 mm
- Network Frequency:
- 50/60 Hz
- Accessory / Separate Part Type:
- shunt trip 110...130 V AC compartment
- Magnetic Tripping Current:
- 1700-1700 A
- Depth:
- 86 mm
- Circuit Breaker Application:
- HACR rated
- Quality Labels:
- CE
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Range:
- PowerPact
- Warranty:
- 18 months
- Product Name:
- PowerPact H
- Mercury Free:
- Yes
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Sustainable Offer Status:
- Green Premium product
- Pollution Degree:
- 3 IEC 60947-1
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Ambient Air Temperature For Operation:
- -2-70 °C
- Communication Interface:
- Modbus || Ethernet
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Continuous Current Rating:
- 0.8
- Control Type:
- toggle
- Pvc Free:
- Yes
- Electrical Connection:
- lugs, line || lugs, load
- Device Application:
- distribution
- Line Rated Current:
- 100-100 A
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Net Weight:
- 2.2 kg
- Color:
- Black
- Suitability For Isolation:
- yes IEC 60947-2
- Breaking Capacity Code:
- G
- Magnetic Hold Current:
- 900 A
- Width:
- 104 mm
- [Ics] Rated Service Breaking Capacity:
- 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Circularity Profile:
- ENVEOLI2206027EN
- Eu Rohs Directive:
- Compliant with Exemptions
- Environmental Disclosure:
- ENVPEP2206027EN
- Product Or Component Type:
- circuit breaker
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quantity Per Set:
- 1
- Wire Stripping Length:
- 16 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Rohs Exemption Information:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View