Schneider Electric

Schneider Electric HGL36125SA Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HGL36125SA
UPC:
7.85902E+11
Condition:
New
Magnetic Tripping Current:
1700-1700 A
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Environmental Disclosure:
ENVPEP2206027EN
Product Name:
PowerPact H
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Mounting Support:
lug
Utilisation Category:
category A
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Mode:
unit mount lug)
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Range:
PowerPact
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Net Weight:
2.2 kg
Device Application:
distribution
Width:
104 mm
Color:
Black
Pollution Degree:
3 IEC 60947-1
Circularity Profile:
ENVEOLI2206027EN
Magnetic Hold Current:
900 A
Warranty:
18 months
Line Rated Current:
125-125 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Wire Stripping Length:
16 mm
[Ics] Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Network Frequency:
50/60 Hz
Depth:
86 mm
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
switched off (OFF) 1 trip indicator green)
Terminal Identifier:
AL150HD
Communication Interface:
Modbus || Ethernet
Continuous Current Rating:
0.8
Quality Labels:
CE
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Pvc Free:
Yes
Poles Description:
3P
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Control Type:
toggle
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
lugs, line || lugs, load
Ambient Air Temperature For Operation:
-2-70 °C
Quantity Per Set:
1
Height:
163 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
UL || CSA || NOM
Suitability For Isolation:
yes IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Breaking Capacity Code:
G
Mercury Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Protected Poles Description:
3t
Eu Rohs Directive:
Compliant with Exemptions
Trip Unit Technology:
thermal-magnetic
Brochure:
View
Catalog:
View
Datasheet:
View
$4,316.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 18kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 3 pole, circuit breaker has a breaking capacity of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose