Schneider Electric HJA260304 Molded Case Circuit Breaker 600V 30A
Schneider Electric
$2,383.50
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 30A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Terminal Identifier:
- AL150HD
- Height:
- 163 mm
- Utilisation Category:
- category A
- Mercury Free:
- Yes
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Mounting Mode:
- I-Line bracket)
- Mounting Support:
- bracket
- Communication Interface:
- Modbus || Ethernet
- Magnetic Tripping Current:
- 750-750 A
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Depth:
- 86 mm
- Ambient Air Temperature For Operation:
- -2-70 °C
- Magnetic Hold Current:
- 350 A
- Width:
- 104 mm
- Mounting Height:
- 4.5 in
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Line Rated Current:
- 30-30 A
- Device Application:
- distribution
- Circuit Breaker Application:
- HACR rated
- Environmental Disclosure:
- ENVPEP1311006EN
- Breaking Capacity Code:
- J
- Poles Description:
- 2P
- Warranty:
- 18 months
- Rohs Exemption Information:
- Yes
- Protected Poles Description:
- 2t
- Pollution Degree:
- 3 IEC 60947-1
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Quality Labels:
- CE
- Range:
- PowerPact
- Color:
- Black
- Product Certifications:
- UL || CSA || NOM
- Product Or Component Type:
- circuit breaker
- Ambient Air Temperature For Storage:
- -50-85 °C
- Net Weight:
- 2.2 kg
- Circularity Profile:
- ENVEOLI1311006EN
- Electrical Connection:
- I-Line connection, line || lugs, load
- Quantity Per Set:
- 1
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Suitability For Isolation:
- yes IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Control Type:
- toggle
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Network Frequency:
- 50/60 Hz
- Product Name:
- PowerPact H
- Trip Unit Technology:
- thermal-magnetic
- Eu Rohs Directive:
- Compliant
- Phase Connection:
- BC
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Wire Stripping Length:
- 16 mm
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View