Schneider Electric HJA260802 Molded Case Circuit Breaker 600V 80A

(No reviews yet) Write a Review
SKU:
HJA260802
UPC:
785901697831
Condition:
New
Communication Interface:
Modbus || Ethernet
Network Frequency:
50/60 Hz
Ambient Air Temperature For Operation:
-2-70 °C
Product Name:
PowerPact H
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Local Signalling:
switched off (OFF) 1 trip indicator green)
Width:
104 mm
Poles Description:
2P
Pvc Free:
Yes
Electrical Connection:
I-Line connection, line || lugs, load
Mounting Height:
4.5 in
Product Certifications:
UL || CSA || NOM
Range:
PowerPact
Circuit Breaker Application:
HACR rated
Trip Unit Technology:
thermal-magnetic
Color:
Black
Quantity Per Set:
1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
163 mm
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant with Exemptions
Wire Stripping Length:
16 mm
Ip Degree Of Protection:
front cover IP40 IEC 60529
Terminal Identifier:
AL150HD
Utilisation Category:
category A
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Quality Labels:
CE
Phase Connection:
AC
Rohs Exemption Information:
Yes
Magnetic Hold Current:
800 A
Continuous Current Rating:
0.8
Protected Poles Description:
2t
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Device Application:
distribution
Magnetic Tripping Current:
1450-1450 A
Mercury Free:
Yes
Warranty:
18 months
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Circularity Profile:
ENVEOLI2206027EN
Line Rated Current:
80-80 A
Ambient Air Temperature For Storage:
-50-85 °C
Depth:
86 mm
Environmental Disclosure:
ENVPEP2206027EN
Mounting Mode:
I-Line bracket)
Suitability For Isolation:
yes IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
2.2 kg
Product Or Component Type:
circuit breaker
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Breaking Capacity Code:
J
Mounting Support:
bracket
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$1,824.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 80A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.