Schneider Electric HJA261002 Molded Case Circuit Breaker 600V 100A

(No reviews yet) Write a Review
SKU:
HJA261002
UPC:
785901795780
Condition:
New
Magnetic Hold Current:
900 A
Rohs Exemption Information:
Yes
Depth:
86 mm
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Utilisation Category:
category A
Ambient Air Temperature For Operation:
-2-70 °C
Sustainable Offer Status:
Green Premium product
Quantity Per Set:
1
Suitability For Isolation:
yes IEC 60947-2
Ip Degree Of Protection:
front cover IP40 IEC 60529
Poles Description:
2P
Width:
104 mm
Ambient Air Temperature For Storage:
-50-85 °C
Device Application:
distribution
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Wire Stripping Length:
16 mm
Mercury Free:
Yes
Mounting Support:
bracket
Network Frequency:
50/60 Hz
Eu Rohs Directive:
Compliant with Exemptions
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
Net Weight:
2.2 kg
Mounting Height:
4.5 in
Product Certifications:
UL || CSA || NOM
Trip Unit Technology:
thermal-magnetic
Pollution Degree:
3 IEC 60947-1
Phase Connection:
AC
Range:
PowerPact
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Communication Interface:
Modbus || Ethernet
Electrical Connection:
I-Line connection, line || lugs, load
Height:
163 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Type:
toggle
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Environmental Disclosure:
ENVPEP2206027EN
Color:
Black
Protected Poles Description:
2t
Product Name:
PowerPact H
Magnetic Tripping Current:
1700-1700 A
Quality Labels:
CE
Line Rated Current:
100-100 A
Local Signalling:
switched off (OFF) 1 trip indicator green)
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
circuit breaker
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Terminal Identifier:
AL150HD
Continuous Current Rating:
0.8
Breaking Capacity Code:
J
Circularity Profile:
ENVEOLI2206027EN
Pvc Free:
Yes
Mounting Mode:
I-Line bracket)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
$1,824.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an AC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose