Schneider Electric HJA261004 Molded Case Circuit Breaker 600V 100A
Schneider Electric
$1,824.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 100A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Terminal Identifier:
- AL150HD
- Mounting Mode:
- I-Line bracket)
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Sustainable Offer Status:
- Green Premium product
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Electrical Connection:
- I-Line connection, line || lugs, load
- Poles Description:
- 2P
- Quality Labels:
- CE
- Warranty:
- 18 months
- Circuit Breaker Application:
- HACR rated
- Breaking Capacity Code:
- J
- Environmental Disclosure:
- ENVPEP2206027EN
- Line Rated Current:
- 100-100 A
- Phase Connection:
- BC
- Utilisation Category:
- category A
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Quantity Per Set:
- 1
- Wire Stripping Length:
- 16 mm
- Control Type:
- toggle
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Product Name:
- PowerPact H
- Device Application:
- distribution
- Mounting Support:
- bracket
- Protected Poles Description:
- 2t
- Communication Interface:
- Modbus || Ethernet
- Pvc Free:
- Yes
- Mercury Free:
- Yes
- Net Weight:
- 2.2 kg
- Magnetic Hold Current:
- 900 A
- Trip Unit Technology:
- thermal-magnetic
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Product Or Component Type:
- circuit breaker
- Range:
- PowerPact
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Width:
- 104 mm
- Suitability For Isolation:
- yes IEC 60947-2
- Height:
- 163 mm
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Color:
- Black
- Depth:
- 86 mm
- Pollution Degree:
- 3 IEC 60947-1
- Eu Rohs Directive:
- Compliant with Exemptions
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Certifications:
- UL || CSA || NOM
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Magnetic Tripping Current:
- 1700-1700 A
- Continuous Current Rating:
- 0.8
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mounting Height:
- 4.5 in
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Circularity Profile:
- ENVEOLI2206027EN
- Rohs Exemption Information:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View