- Color:
- Black
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Terminal Identifier:
- AL150HD
- Breaking Capacity:
- 100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
- Quality Labels:
- CE
- Utilisation Category:
- category A
- Depth:
- 86 mm
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Mounting Height:
- 4.5 in
- Circuit Breaker Application:
- HACR rated
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Product Name:
- PowerPact H
- Control Type:
- toggle
- Device Application:
- distribution
- [Ics] Rated Service Breaking Capacity:
- 100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Communication Interface:
- Modbus || Ethernet
- Height:
- 163 mm
- Trip Unit Technology:
- thermal-magnetic
- Magnetic Hold Current:
- 900 A
- Phase Connection:
- BC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Rohs Exemption Information:
- Yes
- Magnetic Tripping Current:
- 1700-1700 A
- Pvc Free:
- Yes
- Electrical Connection:
- I-Line connection, line || lugs, load
- Product Certifications:
- UL || CSA || NOM
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Line Rated Current:
- 125-125 A
- Mounting Support:
- bracket
- Product Or Component Type:
- circuit breaker
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- Wire Stripping Length:
- 16 mm
- Warranty:
- 18 months
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mercury Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Width:
- 104 mm
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pollution Degree:
- 3 IEC 60947-1
- Ambient Air Temperature For Storage:
- -50-85 °C
- Range:
- PowerPact
- Environmental Disclosure:
- ENVPEP2206027EN
- Mounting Mode:
- I-Line bracket)
- Continuous Current Rating:
- 0.8
- Breaking Capacity Code:
- J
- Net Weight:
- 2.2 kg
- Sustainable Offer Status:
- Green Premium product
- Circularity Profile:
- ENVEOLI2206027EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Quantity Per Set:
- 1
- Poles Description:
- 2P
- Suitability For Isolation:
- yes IEC 60947-2
- Protected Poles Description:
- 2t
- Eu Rohs Directive:
- Compliant with Exemptions
- QN-QUOTE-REQUEST: