Schneider Electric HJA36060SA Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HJA36060SA
UPC:
7.85901E+11
Condition:
New
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Storage:
-50-85 °C
Circularity Profile:
ENVEOLI2206027EN
Ambient Air Temperature For Operation:
-2-70 °C
Width:
104 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Local Signalling:
switched off (OFF) 1 trip indicator green)
Continuous Current Rating:
0.8
Magnetic Tripping Current:
1450-1450 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Wire Stripping Length:
16 mm
Breaking Capacity Code:
J
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Trip Unit Technology:
thermal-magnetic
Pollution Degree:
3 IEC 60947-1
Electrical Connection:
I-Line connection, line || lugs, load
Mercury Free:
Yes
Accessory / Separate Part Type:
shunt trip 110...130 V AC compartment
Height:
163 mm
Utilisation Category:
category A
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Range:
PowerPact
Mounting Mode:
I-Line bracket)
Suitability For Isolation:
yes IEC 60947-2
Warranty:
18 months
Terminal Identifier:
AL150HD
Net Weight:
2.2 kg
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
front cover IP40 IEC 60529
Device Application:
distribution
Pvc Free:
Yes
Mounting Support:
bracket
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Environmental Disclosure:
ENVPEP2206027EN
Mounting Height:
4.5 in
Sustainable Offer Status:
Green Premium product
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Poles Description:
3P
Circuit Breaker Application:
HACR rated
Phase Connection:
ABC
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Depth:
86 mm
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Magnetic Hold Current:
800 A
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Control Type:
toggle
Communication Interface:
Modbus || Ethernet
Quantity Per Set:
1
Rohs Exemption Information:
Yes
Protected Poles Description:
3t
Product Name:
PowerPact H
Color:
Black
Line Rated Current:
60-60 A
Brochure:
View
Catalog:
View
Datasheet:
View
  • Schneider Electric HJA36060SA Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HJA36060SA Molded Case Circuit Breaker 600V 60A
$2,705.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. This unit includes a factory installed 120VAC shunt trip. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose