Schneider Electric HJA36060U33X Molded Case Circuit Breaker 600V 60A

(No reviews yet) Write a Review
SKU:
HJA36060U33X
UPC:
785901275091
Condition:
New
Height:
163 mm
Wire Stripping Length:
16 mm
Breaking Capacity Code:
J
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Width:
104 mm
Poles Description:
3P
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Mounting Height:
4.5 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Line Rated Current:
60-60 A
Terminal Identifier:
AL150HD
Network Frequency:
50/60 Hz
Trip Unit Name:
MicroLogic 3.2 S
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Or Component Type:
circuit breaker
Color:
Black
Warranty:
18 months
Ambient Air Temperature For Operation:
-2-70 °C
Ip Degree Of Protection:
front cover IP40 IEC 60529
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-2
Pvc Free:
Yes
Communication Interface:
Modbus || Ethernet
Mounting Mode:
I-Line bracket)
Mounting Support:
bracket
Device Application:
distribution
Product Name:
PowerPact H
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
Protected Poles Description:
3t
Electrical Connection:
I-Line connection, line || lugs, load
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Mercury Free:
Yes
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Range:
PowerPact
Trip Unit Technology:
electronic, standard, MicroLogic 3.2 S, LSI
Sustainable Offer Status:
Green Premium product
Phase Connection:
ABC
Ambient Air Temperature For Storage:
-50-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Quality Labels:
CE
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Control Type:
toggle
Environmental Disclosure:
ENVPEP2206028EN
Depth:
86 mm
Continuous Current Rating:
0.8
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Rohs Exemption Information:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Net Weight:
2.2 kg
Circularity Profile:
ENVEOLI2206028EN
Quantity Per Set:
1
Eu Rohs Directive:
Compliant with Exemptions
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Utilisation Category:
category A
Circuit Breaker Application:
HACR rated
  • Schneider Electric HJA36060U33X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HJA36060U33X Molded Case Circuit Breaker 600V 60A
  • Schneider Electric HJA36060U33X Molded Case Circuit Breaker 600V 60A
$2,420.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 60A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.