Schneider Electric HJA36150U33X Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HJA36150U33X
UPC:
7.85902E+11
Condition:
New
Product Certifications:
UL || CSA || NOM
Trip Unit Technology:
electronic, standard, MicroLogic 3.2 S, LSI
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Quality Labels:
CE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
104 mm
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Color:
Black
Pollution Degree:
3 IEC 60947-1
Net Weight:
2.2 kg
Product Or Component Type:
circuit breaker
Continuous Current Rating:
0.8
Ambient Air Temperature For Storage:
-50-85 °C
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Communication Interface:
Modbus || Ethernet
Height:
163 mm
Environmental Disclosure:
ENVPEP2206028EN
Wire Stripping Length:
16 mm
Phase Connection:
ABC
Protected Poles Description:
3t
Circuit Breaker Application:
HACR rated
Utilisation Category:
category A
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Pvc Free:
Yes
Device Application:
distribution
Warranty:
18 months
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Quantity Per Set:
1
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Name:
MicroLogic 3.2 S
Ip Degree Of Protection:
front cover IP40 IEC 60529
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Rohs Exemption Information:
Yes
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity Code:
J
Circularity Profile:
ENVEOLI2206028EN
Electrical Connection:
I-Line connection, line || lugs, load
Range:
PowerPact
Mounting Mode:
I-Line bracket)
Line Rated Current:
150-150 A
Control Type:
toggle
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Height:
4.5 in
Poles Description:
3P
Depth:
86 mm
Terminal Identifier:
AL150HD
Network Frequency:
50/60 Hz
Product Name:
PowerPact H
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mercury Free:
Yes
Mounting Support:
bracket
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
  • Schneider Electric HJA36150U33X Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HJA36150U33X Molded Case Circuit Breaker 600V 150A
$5,823.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Standard with a 3.2S trip unit and an LSI function with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose