Schneider Electric HJA36150U53X Molded Case Circuit Breaker 600V 150A

(No reviews yet) Write a Review
SKU:
HJA36150U53X
UPC:
7.85902E+11
Condition:
New
Mounting Mode:
I-Line bracket)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Certifications:
UL || CSA || NOM
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Product Name:
PowerPact H
Wire Stripping Length:
16 mm
Mounting Height:
4.5 in
Ambient Air Temperature For Storage:
-50-85 °C
Protected Poles Description:
3t
Circularity Profile:
ENVEOLI2206028EN
Trip Unit Name:
MicroLogic 5.2 E
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Ambient Air Temperature For Operation:
-2-70 °C
Electrical Connection:
I-Line connection, line || lugs, load
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Local Signalling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Mounting Support:
bracket
Environmental Disclosure:
ENVPEP2206028EN
Phase Connection:
ABC
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Communication Interface:
Modbus || Ethernet
Range:
PowerPact
Breaking Capacity Code:
J
Depth:
86 mm
Poles Description:
3P
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
104 mm
Network Frequency:
50/60 Hz
Terminal Identifier:
AL150HD
Control Type:
toggle
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Net Weight:
2.2 kg
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Color:
Black
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Line Rated Current:
150-150 A
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Utilisation Category:
category A
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Warranty:
18 months
Trip Unit Technology:
electronic, energy, MicroLogic 5.2 E, LSI
Pvc Free:
Yes
Quantity Per Set:
1
Height:
163 mm
Product Or Component Type:
circuit breaker
Suitability For Isolation:
yes IEC 60947-2
Device Application:
distribution
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40 IEC 60529
  • Schneider Electric HJA36150U53X Molded Case Circuit Breaker 600V 150A
  • Schneider Electric HJA36150U53X Molded Case Circuit Breaker 600V 150A
$6,833.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides Micrologic Energy with a 5.2E trip unit and an LSI function with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 150A, 3 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose