Schneider Electric

Schneider Electric HJL26125 Molded Case Circuit Breaker 600V 125A

(No reviews yet) Write a Review
SKU:
HJL26125
UPC:
7.85902E+11
Condition:
New
[Ics] Rated Service Breaking Capacity:
100 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 65 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 25 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
Rohs Exemption Information:
Yes
Device Application:
distribution
Pvc Free:
Yes
Warranty:
18 months
Awg Gauge:
AWG 14...AWG 3/0 aluminium/copper terminal
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Mode:
unit mount lug)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Circuit Breaker Application:
HACR rated
Continuous Current Rating:
0.8
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Certifications:
UL || CSA || NOM
Trip Unit Technology:
thermal-magnetic
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Magnetic Hold Current:
900 A
Product Name:
PowerPact H
Poles Description:
2P
Line Rated Current:
125-125 A
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Eu Rohs Directive:
Compliant with Exemptions
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Width:
104 mm
Suitability For Isolation:
yes IEC 60947-2
Color:
Black
Circularity Profile:
ENVEOLI2206027EN
Magnetic Tripping Current:
1700-1700 A
Terminal Identifier:
AL150HD
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Depth:
86 mm
Mounting Support:
lug
Network Frequency:
50/60 Hz
Wire Stripping Length:
16 mm
Breaking Capacity Code:
J
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Or Component Type:
circuit breaker
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Electrical Connection:
lugs, line || lugs, load
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2206027EN
Utilisation Category:
category A
Ambient Air Temperature For Storage:
-50-85 °C
Quality Labels:
CE
Communication Interface:
Modbus || Ethernet
Net Weight:
2.2 kg
Ip Degree Of Protection:
front cover IP40 IEC 60529
Sustainable Offer Status:
Green Premium product
Quantity Per Set:
1
Protected Poles Description:
2t
Control Type:
toggle
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Pollution Degree:
3 IEC 60947-1
Local Signalling:
switched off (OFF) 1 trip indicator green)
Height:
163 mm
Tightening Torque:
5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
Brochure:
View
Catalog:
View
Datasheet:
View
$4,449.00

Description

PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 25kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. This breaker has lugs on both the line and load sides. This PowerPacT H, 125A, 2 pole, circuit breaker has a breaking capacity of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose