Schneider Electric HLA36080 Molded Case Circuit Breaker 600V 80A
Schneider Electric
$3,243.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 80A, 3 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Protected Poles Description:
- 3t
- Phase Connection:
- ABC
- Depth:
- 86 mm
- Ip Degree Of Protection:
- front cover IP40 IEC 60529
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Utilisation Category:
- category A
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- [Ics] Rated Service Breaking Capacity:
- 125 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Mounting Support:
- bracket
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Suitability For Isolation:
- yes IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85 °C
- Width:
- 104 mm
- Magnetic Tripping Current:
- 1450-1450 A
- Net Weight:
- 2.2 kg
- Continuous Current Rating:
- 0.8
- Sustainable Offer Status:
- Green Premium product
- Electrical Connection:
- I-Line connection, line || lugs, load
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Color:
- Black
- Eu Rohs Directive:
- Compliant with Exemptions
- Quality Labels:
- CE
- Poles Description:
- 3P
- Breaking Capacity Code:
- L
- Awg Gauge:
- AWG 14...AWG 3/0 aluminium/copper terminal
- Communication Interface:
- Modbus || Ethernet
- Environmental Disclosure:
- ENVPEP2206027EN
- Magnetic Hold Current:
- 800 A
- Rohs Exemption Information:
- Yes
- Warranty:
- 18 months
- Trip Unit Technology:
- thermal-magnetic
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-3
- Terminal Identifier:
- AL150HD
- Height:
- 163 mm
- Mounting Mode:
- I-Line bracket)
- Wire Stripping Length:
- 16 mm
- Network Frequency:
- 50/60 Hz
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Pvc Free:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Range:
- PowerPact
- Circuit Breaker Application:
- HACR rated
- Line Rated Current:
- 80-80 A
- Product Name:
- PowerPact H
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quantity Per Set:
- 1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Control Type:
- toggle
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Product Or Component Type:
- circuit breaker
- Circularity Profile:
- ENVEOLI2206027EN
- Breaking Capacity:
- 125 kA 240 V AC 50/60 Hz UL 489 || 100 kA 480 V AC 50/60 Hz UL 489 || 50 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 50 kA 500 V DC UL 489
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Pollution Degree:
- 3 IEC 60947-1
- Mounting Height:
- 4.5 in
- Device Application:
- distribution
- Tightening Torque:
- 5-5 N.m 2.5-6 mm² (AWG 14...AWG 10) || 14-14 N.m 10-95 mm² (AWG 8...AWG 3/0)
- Ambient Air Temperature For Operation:
- -2-70 °C
- Mercury Free:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View